Supersider 1 in Step Flashing 26ga White - Sold by Foot
Supersider 1 in Step Flashing 26ga White - Sold by Foot
Couldn't load pickup availability
26ga White | 4 in Wall Leg | 1 in Step | Sold by Foot | 8 ft Max Ship Length
Supersider 1 in Step Flashing 26ga White - Sold by Foot
Protect the roof-to-wall transition before water finds the weak spot with a white 26ga flashing profile built for siding edges, low-slope roof details, and gutter-adjacent water control.
Clear Ordering Note: Sold by Foot, Shipping Length Limited to 8 ft
This flashing is priced and sold by the foot. Select the total footage needed for the run, repair, or fabrication plan. Because long metal pieces are expensive and difficult to ship safely, shipped lengths must be limited to 8 ft or shorter.
- Sold by foot: order the total number of feet needed.
- Maximum shipped length: 8 ft per piece due to the cost and handling risk of long items.
- Longer pieces: use in-store pickup or local delivery when available.
- Color: white finish.
- Check before ordering: confirm total footage, piece length, roof-to-wall detail, siding overlap, and whether pickup, local delivery, or shipping is the right choice.
Key Benefits at a Glance
Controls Water at the Wall Line
Helps direct roof runoff away from vulnerable roof-to-wall and siding transitions when installed as part of the full drainage detail.
4 in Vertical Wall Leg
Provides wall-side coverage for siding overlap and transition work where the flashing must rise behind exterior cladding.
Sold by Foot
Lets contractors match the order to the actual run length instead of buying a fixed quantity that does not fit the job.
8 ft Shipping Limit
Keeps shipped pieces realistic for carrier handling while giving local buyers pickup and delivery options for longer pieces.
Roof-to-Wall Water Damage Starts Small, Then Gets Expensive
The roof edge, wall line, siding overlap, and gutter area all meet in a narrow zone where water can slip behind finishes if the metal transition is not planned correctly. That can lead to stained siding, soft sheathing, hidden rot, callbacks, and repairs that cost far more than the flashing detail.
This Supersider 1 in step flashing gives installers a defined metal profile for those vulnerable transition areas: a 4 in wall leg, 1 in step, white 26ga metal construction, and sold-by-foot ordering for measured roof-to-wall runs.
Built for Clean Roof, Siding, and Gutter Transitions
Supersider 1 in Step Flashing is a white 26ga metal flashing profile for roof-to-wall, siding, and gutter-adjacent transition details. The profile image shows a 4 in vertical leg, 1 in step, and lower return detail marked 3/8 in, 3/8 in, and 1/4 in.
For gutter installers and exterior contractors, the value is cleaner water management at the point where roof runoff, wall cladding, and gutter systems interact. The flashing helps create a controlled transition where siding, roofing, and drainage components need to work together instead of leaving water a path behind the wall finish.
This product is sold by the foot. Shipped pieces must be 8 ft or shorter because long flashing is costly to package and ship safely. For longer pieces, choose in-store pickup at GutterAll in Damascus, Oregon or ask about local delivery before checkout.
Use website chat first for help confirming total footage, piece length, color, roof-to-wall detail, siding overlap, and fulfillment option. Email and phone are available as secondary support options.
| Product | Key Specs |
|---|---|
| Supersider 1 in Step Flashing 26ga White - Sold by Foot | White 26ga metal flashing profile with 4 in vertical leg, 1 in step, lower return detail shown as 3/8 in, 3/8 in, and 1/4 in; sold by foot; shipped lengths limited to 8 ft; longer pieces require pickup or local delivery where available. |
Why This Flashing Detail Matters
Roof-to-wall transitions are one of the first places exterior water control can fail because water is moving from the roof plane toward a wall, siding edge, gutter, or termination point. If the metal detail is missing, undersized, poorly lapped, or cut too short, water can move behind the finished surface.
This profile gives contractors a measured flashing option for transition work where a compact step and tall wall leg are needed. It is useful for siding integration, low-slope edge details, wall transition repairs, and gutter-adjacent water control when the job calls for this shape and size.
The cleanest order starts with three checks: the total footage needed, the longest piece length needed, and whether the material is being picked up, delivered locally, or shipped in 8 ft or shorter pieces.
Contractor Applications
| Application | Why It Helps |
|---|---|
| Roof-to-wall transitions | Helps create a metal water-control layer where the roof edge meets siding or a vertical wall. |
| Gutter-adjacent siding details | Supports cleaner routing where runoff approaches the gutter, wall edge, or drainage termination area. |
| Low-slope edge work | The compact 1 in step is useful when the project calls for a lower-profile transition detail. |
| Siding replacement and repair | Allows installers to address the hidden water-control layer before new siding or trim covers the wall line. |
| Measured flashing runs | Sold-by-foot ordering helps match the footage to the actual wall, roof, or gutter-adjacent run. |
How the Flashing Profile Works
The 4 in vertical leg rises behind siding, trim, or the wall-side covering. The 1 in step projects out to bridge the transition area. The lower formed return helps finish the profile edge and gives the piece its Supersider shape.
Installed correctly, flashing works as part of a layered water-control system. Roofing, siding, housewrap or weather barrier, kick-out flashing where needed, fasteners, sealant, and gutter placement all need to work together so runoff moves outward and down instead of behind the wall.
Choose the Right Flashing Setup
This Product: Supersider 1 in Step Flashing
Best when the project calls for this white 26ga profile with a 4 in wall leg, 1 in step, and measured footage ordering.
Standard Step Flashing Pieces
Better when the roof detail requires individual step pieces woven course by course with roofing materials.
Kick-Out Flashing
Needed at roof-wall termination points when runoff must be directed outward and into the gutter instead of down the wall face.
Key Features
| Feature | Detail | Installer Benefit |
|---|---|---|
| 26ga metal | White metal flashing profile | Gives exterior crews a formed flashing piece for siding and roof transition work. |
| 4 in vertical leg | Wall-side leg shown in profile image | Helps tuck the flashing behind siding, trim, or wall-side materials. |
| 1 in step | Compact horizontal step | Useful where the detail calls for a low-profile roof-to-wall transition. |
| Lower return profile | 3/8 in, 3/8 in, and 1/4 in detail shown | Creates the formed Supersider edge shown in the profile diagram. |
| Sold by foot | Order total footage needed | Helps match the order to the measured run without overbuying fixed bundles. |
| 8 ft max ship length | Shipping length capped for long-piece cost and handling | Keeps delivery expectations clear before checkout and reduces long-item shipping surprises. |
Summary
Choose Supersider 1 in Step Flashing when the job calls for a white 26ga roof-to-wall or siding transition profile sold by the foot. Confirm the measured footage, piece length, shipping limit, pickup or delivery option, siding overlap, water path, and whether kick-out flashing or other transition parts are also needed.
Key Benefits
- Helps protect roof-to-wall and siding transitions from water entry
- Useful near gutters where runoff needs a controlled path
- 4 in wall leg supports siding overlap and wall-side coverage
- 1 in step supports compact low-profile transition details
- White finish coordinates with common trim, fascia, and siding colors
- Sold by foot for accurate job planning
- Clear 8 ft shipping length limit avoids long-item freight confusion
- Longer pieces can be planned for pickup or local delivery where available
- Useful for gutter installers, siding crews, roofers, remodelers, and repair techs
- Helps finish exposed transition areas more cleanly than improvised flat stock
- Supports repair work where old flashing is missing, short, bent, or poorly overlapped
- Can be cut to fit field conditions with appropriate metal tools
- Works as part of a layered exterior water-control system
- Helps contractors quote and order by measured run length
- GutterAll can help confirm footage and fulfillment through website chat
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Supersider 1 in Step Flashing 26ga White - Sold by Foot |
| Product Type | Step flashing, siding flashing, roof-to-wall flashing, wall transition flashing, metal flashing profile |
| Material | 26ga metal |
| Color | White |
| Vertical Wall Leg | 4 in |
| Step Projection | 1 in |
| Lower Profile Detail | 3/8 in, 3/8 in, and 1/4 in dimensions shown in profile diagram |
| Selling Format | Sold by foot |
| Shipping Length Limit | 8 ft maximum shipped length due to long-item shipping cost and handling risk |
| Longer Length Fulfillment | Use in-store pickup or local delivery where available for longer pieces |
| Primary Use | Roof-to-wall transitions, siding integration, gutter-adjacent water control, low-slope edge details, exterior repair work |
| Common Users | Gutter installers, siding contractors, roofing crews, remodelers, builders, repair techs, and capable DIY homeowners |
| Field Work | May require cutting, fitting, lapping, fastening, and integration with siding, roofing, weather barrier, and gutter components |
| Not Intended For | Incorrect roof profiles, unsupported piece lengths, missing kick-out details, poor siding overlap, or projects requiring a different metal, color, gauge, or profile |
| Expected Service Life | Varies by coating condition, cut edges, fastening, drainage design, siding overlap, roof exposure, maintenance, salt exposure, installation quality, and contact with other metals. |
Who Uses This Flashing?
Gutter Installers and Exterior Crews
- Detailing roof, siding, and gutter-adjacent transition areas
- Ordering measured footage for repair or replacement work
- Planning pickup, local delivery, or 8 ft shipped pieces before the job date
Roofers, Siding Contractors, and Remodelers
- Replacing missing or damaged transition flashing during exterior work
- Integrating flashing with siding, trim, wall covering, and roofing details
- Coordinating kick-out flashing, step flashing, and drainage plane details where needed
Capable DIY Homeowners and Property Owners
- Ordering measured flashing for repair areas or contractor-installed projects
- Confirming whether shipping, pickup, or local delivery makes sense for the required length
- Checking with a qualified installer when the roof, wall, or water path is unclear
Setup and Application Guide
- Measure the total roof-to-wall or siding transition length that needs flashing.
- Decide the piece lengths needed before ordering, remembering that shipped pieces are limited to 8 ft.
- Choose pickup or local delivery for longer pieces where available.
- Confirm the white 26ga profile matches the exterior finish, siding detail, and project requirement.
- Check that the 4 in wall leg and 1 in step fit the intended roof and siding transition.
- Plan lapping, siding overlap, kick-out flashing, and drainage path before fastening.
- Cut flashing with appropriate metal tools and protect cut edges where the project requires it.
- Install flashing as part of the full roof, wall, siding, and drainage assembly.
- Direct runoff outward and toward the gutter or approved drainage point.
- Inspect the finished detail for gaps, reverse laps, open seams, sharp edges, loose fasteners, and areas where water can move behind the wall covering.
Pro Tip
Before cutting, mock up the flashing with a short sample at the roof-to-wall transition. Check siding overlap, gutter outlet location, roof slope, and whether a kick-out piece is needed at the bottom of the run. One dry-fit can prevent a whole run from being ordered or cut wrong.
Frequently Asked Questions
What is Supersider 1 in Step Flashing used for?
It is used for roof-to-wall, siding, and gutter-adjacent transition details where a white 26ga metal flashing profile with a 4 in wall leg and 1 in step is needed.
How is this flashing priced and sized?
It is sold by the foot. Select the total footage needed for the run. Shipped pieces must be 8 ft or shorter; longer pieces should be handled by pickup or local delivery where available.
Can pieces longer than 8 ft be shipped?
No. Shipping length is limited to 8 ft because long flashing is costly to package and ship safely. For longer pieces, use in-store pickup or ask about local delivery.
Does this replace kick-out flashing?
No. Kick-out flashing may still be needed where a roof-wall run terminates and water must be directed outward into the gutter. This flashing is one part of the full water-control detail.
What is GutterAll's return policy for this product?
GutterAll offers a 30-day return window for unused standard products in original condition. Cut, bent, scratched, installed, altered, custom-length, custom-color, or damaged flashing may not be returnable unless defective. Customers should confirm footage, piece length, color, profile, pickup, delivery, and shipping limits before ordering. Return shipping or return transport is the buyer's responsibility unless the return is due to defect or shipping error. Refunds are processed within 5 to 7 business days after approval and receipt.
What fulfillment options are available?
In-store pickup at GutterAll in Damascus, Oregon, local delivery where available, and shipping are available depending on selected piece length. Shipped pieces are limited to 8 ft. Typical small-order handling is 1 to 2 business days, and transit time is typically 3 to 7 business days depending on destination and carrier.
Cutting, Handling, and Installation Safety Notice
Metal flashing can have sharp edges, especially after cutting. Use gloves, eye protection, safe cutting tools, and proper handling practices.
Roof, siding, and gutter work may involve ladders, roof edges, power tools, and fall hazards. Use safe access methods and follow applicable jobsite safety requirements.
Flashing must be integrated with the full exterior water-control system. Poor lapping, missing kick-out details, exposed gaps, weak fastening, or incompatible metals can reduce performance.
Need Help Confirming Footage, Piece Length, or the Right Transition Detail?
The right order depends on total footage, piece length, shipping limit, roof-to-wall layout, siding overlap, color, pickup, delivery, and whether additional flashing pieces are needed. Website chat is the fastest way to confirm before checkout.
Fastest Path
Start with website chat for footage, profile, piece length, and fulfillment questions.
Complete the Detail
Add related flashing, kick-out pieces, fasteners, sealant, trim, siding, or gutter parts separately as needed.
Fulfillment Options
In-store pickup, local delivery, and shipping are available depending on selected piece length. Shipped lengths must be 8 ft or shorter.
Product Summary Box
Supersider 1 in Step Flashing 26ga White is a sold-by-foot roof-to-wall and siding transition flashing profile with a 4 in vertical leg, 1 in step, and lower return detail. It is used for gutter-adjacent water-control work, siding transitions, low-slope edge details, and exterior repair projects where the selected piece length and water path must be planned before ordering.
Address
GutterAll
19759 SE Sunnyside Rd
Damascus, OR 97089
Hours
Mon-Fri: 7am-4pm PST
Sat: 9am-12pm PST
sales@gutterall.com
Phone
(503) 850-6784